| Item |
PAC60-1R |
| Output voltage |
0 to 60V |
| Outputcurrent |
0 to 1A |
| Constantvoltage characteristics |
| Input regulation |
ForAC±10% fluctuation |
8mV |
| Load regulation |
For0to100% fluctuation |
8mV |
| Ripple andnoise |
10Hz TO 1MHz |
1mVrms |
| Ripple peak |
10Hzto 20MHz |
4mVp-p |
| Transient respones |
Standrdvalue(current5% to 100%) |
50μs Typical |
| Temperature coefficient |
Standardvalue |
100ppm/℃ Typical |
| Constantcurrent characreristis |
| Input regulation |
For AC±10%fluctuation |
2mA |
| Load regulation |
For 0to 100%fluctration |
10mA |
| Ripple and noise |
10Hz to 1MHz |
1mArms |
| Temperature coefficient |
Standard value |
250ppm/℃ Typical |
| Digital meter indicatoin |
| Voltmeter indication |
Red 3-digit LED |
Max.99.9V,fixed range |
| Accuracy |
Output ON |
±(0.2%rdg+2digits) |
| Ammeter indication |
Red 3-digit LED |
Max.99.9A,fixed range |
| Accuracy |
Output ON |
±(1.0%rdg+3digits) |
| Operating conditions(indoor use only) |
| Cooling method |
|
Natural air cooling |
| Output polarity |
|
+(red),-(white),GND(black),±grounding possible |
| Ground proof voltage |
|
±200v |
| Powder |
| Input power |
Voltage fluctuation,within±10% |
AC100V/120V/220V/230V, Selectable |
| Input power |
(Approx.) |
145VA/100W |
| Dimension,weight |
| Dimensions |
Width×height×depth(mm) |
134×147×322 |
| Max.dimensions |
Width×height×depth(mm) |
138×162×345 |
| Weight |
|
5.8kg |
| Accessories |
|
One instruction manual,one powercable |